Categories

Table Top Spectrophotometer

Table Top Spectrophotometer LX100TS

Table Top Spectrophotometer : Table Top Spectrophotometer LX100TS
  • Illumination system :d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology)
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere :40 mm, alvan diffused reflection surface coating
  • Illumination light source :CLED
  • Sensor :Dual light path sensor array

Table Top Spectrophotometer LX101TS

Table Top Spectrophotometer : Table Top Spectrophotometer LX101TS
  • Illumination system :d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology)
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere :40 mm, alvan diffused reflection surface coating
  • Illumination light source :CLED
  • Sensor :Dual light path sensor array

Table Top Spectrophotometer LX102TS

Table Top Spectrophotometer : Table Top Spectrophotometer LX102TS
  • Illumination system :d/8 (Diffused lighting, 8° observation angle)
    SCS optical engine (light splitting and integration system)
    ETC (real time calibration technology)
    SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere :15.2 cm, alvan diffused reflection surface coating
  • Illumination light source :CLED
  • Sensor :Dual light path sensor array

Table Top Spectrophotometer LX103TS

Table Top Spectrophotometer : Table Top Spectrophotometer LX103TS
  • Illumination system :d/0 (Diffused lighting, 0° observation viewing), SCS optical engine (light splitting and integration system), ETC (every time calibration technology), SCI (specular reflection included)/ SCE (specular reflection excluded) simultaneous measurement
  • Size of integrated sphere :40 mm, alvan diffused reflection surface coating
  • Illumination light source :CLED
  • Sensor :Dual light path sensor array

Table Top Spectrophotometer LX104TS

Table Top Spectrophotometer : Table Top Spectrophotometer LX104TS
  • Light source :LED
  • Wavelength range :400-700 nm
  • Wavelength interval :10 nm
  • Sensor :High sensitivity silicon photodiode

Table Top Spectrophotometer LX105TS

Table Top Spectrophotometer : Table Top Spectrophotometer LX105TS
  • Wavelength Range :360 nm to 780 nm
  • Wavelength Pitch :10 nm
  • Sensor :Silicon Photodiode Array
  • Grating Method :Concave Grating