Analyzers
Analysis Method: Coagulation method
Analysis Items: PT, APTT, TT, FIB
Throughput: 140 Tests/hour
SamplePositions: 5
Measuring Element: Grain
Moisture Range: 3 % to 35 %
Repeating Error: ≤ 0.2 %
Measuring Error: ≤ ± 0.5 %
Throughput: 200 Tests/hour
Analysis Method: End-point, Fixed-time, Rate(Kinetic)
Sample Positions: 37 sample positions
Reagent Position: 28 reagent positions
Throughput: 200 Tests/hour
Analysis Method: End-point, Fixed-time, Rate(Kinetic)
Sample Positions: 49 sample positions
Reagent Position: 56 reagent positions
Throughput: 400 Test/hour
Analysis Method: End-point, Fixed-time, Rate(Kinetic)
Sample Positions: 60 or 90 sample positions, built-in barcode system available
Reagent Position: 90 refrigerated reagent positions
Throughput: 600Tests/hour
Analysis Method: End-point, Fixed-time, Rate, Two-point, Turbidimetry
Sample Positions: 90 sample positions, built-in barcode system available
Reagent Position: 180 refrigerated reagent positions(R1:45 & R2:45)
Throughput: 800Tests/hour, 1200Tests/hour with ISE (Optional)
Analysis Method: End-point, Fixed-time, Rate(Kinetic), Turbidimetry
Sample Positions: 150 sample positions
Reagent Position: 180 reagent positions
Sample: Whole blood, Serum, Plasma, Dialysate, CSF
Input Parameters: Patient Temperature, Hemoglobin, FiO2, B.P.
Analysis Time: <90s
Test: pH(CH), pCO2, pO2, K,Na+, CL-, Ca++, Hct, B.P.
Sample: Whole blood, Serum, Plasma, Dialysate, CSF
Input Parameters: Patient Temperature, Hemoglobin, FiO2, B.P.
Analysis Time: <90s
Test: pH(CH), pCO2, pO2, K,Na+, CL-, Ca++, Hct, B.P.
Test Items: K, Na, Cl
Sample: Serum, plasma, whole blood, cerebrospinal fluid and dilute urine
Measuring Speed: ≤25s
Analysis Method: lon selective electrode (ISE)
Test Items: K, Na, Cl, TCO2, AG
Sample: Serum, plasma, whole blood, cerebrospinal fluid and dilute urine
Measuring Speed: ≤25s
Analysis Method: lon selective electrode (ISE)
Test Items: K, Na, Cl, iCa, nCa, TCa, pH
Sample: Serum, plasma, whole blood, cerebrospinal fluid and dilute urine
Measuring Speed: ≤25s
Analysis Method: lon selective electrode (ISE)
Test Items: K, Na, Cl, iCa, nCa, TCa, pH, TCO2, AG
Sample: Serum, plasma, whole blood, cerebrospinal fluid and dilute urine
Measuring Speed: ≤25s
Analysis Method: lon selective electrode (ISE)
Test Items: K, Na, Cl, Li
Sample: Serum, plasma, whole blood, cerebrospinal fluid and dilute urine
Measuring Speed: ≤25s
Analysis Method: lon selective electrode (ISE)
Test Items: K, Na, Cl, iCa, nCa, TCa, pH, Li
Sample: Serum, plasma, whole blood, cerebrospinal fluid and dilute urine
Measuring Speed: ≤25s
Analysis Method: lon selective electrode (ISE)
Test Items: K, Na, Cl, iCa, nCa, TCa, pH, Li, TCO2, AG
Sample: Serum, plasma, whole blood, cerebrospinal fluid and dilute urine
Measuring Speed: ≤25s
Analysis Method: lon selective electrode (ISE)
Test Items: K, Na, Cl, iCa, nCa, TCa, pH, Mg
Sample: Serum, plasma, whole blood, cerebrospinal fluid and dilute urine
Measuring Speed: ≤25s
Analysis Method: lon selective electrode (ISE)
Test Items: K, Na, Cl, iCa, nCa, TCa, pH, Li, Mg, TCO2, AG
Sample: Serum, plasma, whole blood, cerebrospinal fluid and dilute urine
Measuring Speed: ≤25s
Analysis Method: lon selective electrode (ISE)
Application: Erythrocyte sedimentation rate analysis
Measuring: Principle Infrared sensor
Analysis Result: Westergren ESR value(mm/hr)
Throughput: Up to 80 samples per hour
Application: Erythrocyte sedimentation rate analysis
Measuring: Principle Infrared sensor
Analysis Result: Westergren ESR value(mm/hr)
Throughput: Up to 80 samples per hour
Temperature Range: RT +5℃~300℃
Measuring Range: 0.1~100%
Temperature Accuracy: ±1℃
Repeatability: Relative error 1%
Temperature Range: RT +5℃~300℃
Measuring Range: 0~100%
Temperature Accuracy: ±1℃
Sample Weight: 0.5~15g
Throughput: 60 tests/hour
Measuring Principle: Coulter principle Colorimetry hemoglobin determination
Parameter: WBC, LY#, MID#, GR#, LY%, MID%, GR%, RBC, HGB
HCT,MCV, MCH, MCHC, RDW-SD
RDW-CV, PLT, MPV, PDW, PCT, P-LCR, P-LCC
Histograms: 3 Histograms (including WBC, RBC, PLT)
Throughput: 60 tests/hour
Measuring Principle: Impedance for cell counting Cyanide-free method for HGB
Aperture Diameter: WBC chamber:100μm,RBC/PLT chamber:70μm
Parameter: WBC, Neu#, Lym#, Mid#, Neu%,Lym%, Mid%, RBC, HGB, HCT, MCV, MCH, MCHC,RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, P-LCR
Throughput: 60 tests/hour
Assay Items: 5 parts, 29parameters, 3 histograms, 3Dscattergram
Principle: Tri-angle laser scatter, Flow cytometrymethod, 3D scattergram analysis, Impedancemethodfor RBC and PLT counting, Cyanide-free method for HGB test
Test Mode: CBC mode, CBC+DIFF mode Venous whole blood, Capillary whole blood and Prediluted
Function: Chemistry + Coagulation
Photometry method: End point, fixed time, kinetic, serum blank, Bi-chromatic, two reagent, multi-point etc.
Coagulation method: Nephelometry
Specific protein method: Nephelometry, kinetic Nephelometry
Function: Chemistry + Specific Protein
Photometry method: End point, fixed time, kinetic, serum blank, Bi-chromatic, two reagent, multi-point etc.
Coagulation method: Nephelometry
Specific protein method: Nephelometry, kinetic Nephelometry
Function: Chemistry + Coagulation + Specific Protein
Photometry method: End point, fixed time, kinetic, serum blank, Bi-chromatic, two reagent, multi-point etc.
Coagulation method: Nephelometry
Specific protein method: Nephelometry, kinetic Nephelometry
Reading cuvette: Quartz flow through cell
Measuring volume: 450μl-800μl
Incubator: 20 incubating positions
Test: T.BILI r-GT/GGT CHO Ca APOB-1/B CHE
D.BILI ALP/AKP TG CL APOB CREA
TP UREA CK P CK-MB Mg
ALB LDH C ASO AFU Lactic Acid
ALT/GPT UA ɑ-HBDH CO₂ FMN LP(a)
AST/GOT GLU AMY LDL-C HD-C LA
TBA ADA HS-CRP PA Fe Cu
Zn C₃ C₄ IgG
IgM IgA and drug, toxicity, etc.
Reading cuvette: Quartz flow through cell
Measuring volume: 450μl-800μl
Test: T.BILI r-GT/GGT CHO Ca APOB-1/B CHE
D.BILI ALP/AKP TG CL APOB CREA
TP UREA CK P CK-MB Mg
ALB LDH C ASO AFU Lactic Acid
ALT/GPT UA ɑ-HBDH CO₂ FMN LP(a)
AST/GOT GLU AMY LDL-C HD-C LA
TBA ADA HS-CRP PA Fe Cu
Zn C₃ C₄ IgG
IgM IgA and drug, toxicity, etc.
Quality Control: Excellent Q.C.function, Chart may be displayed and printed
Measurement Range: 0-10000 mg/l
Detection Limit: 5 μg/l (ppb)
Digestion Mode: Wet chemical Oxidation by UV
Detector: NDIR
Measurement Range: 0-30000 mg/l
Detection Limit: 50 μg/l (ppb)
Digestion Mode: High Temperature Combustion
Detector: NDIR
Type: Offline
Measurement range: 0.001 to 1.5 mg/L (ppm)
Detection limit: 1 ppb
Maximum tolerance: ± 5%
Type: Online
Measurement range: 0.001 to 1.5 mg/L (ppm)
Detection limit: 1 ppb
Maximum tolerance: ± 5%
Throughput: 120 Tests/hour
Display: LCD display
Test Items: PH, Nitrite, Protein, Glucose, Occult blood, Bilirubin, Urobilinogen, Ketone, Specific gravity, Leukocytes, Ascorbic Acid, Color, Limpidness
Principle: Reflection of high-brightness cold light
Measurement Principle: Albedometry
Test Items: 14 items, including GLU, BIL, KET, SG, pH, BLD, PRO, URO, NIT, LEU, VC, CRE, CAL, MAL
Test Speed: 60-120 Tests/hour
Display: LCD display
Measurement Principle: Artificial Intelligence + Computer Perception Technology
Test Items: 14 items, including GLU, BIL, KET, SG, pH, BLD, PRO, URO, NIT, LEU, VC, CRE, CAL, MAL
Test Speed: 514 Tests/hour
Display: 7 inch touch screen
Assay Method: Albedometry
Test Speed: 240 Tests/hour
Sample Racks: 5 test tube racks(5*10 samples)
Sample Volume: Not lower than the marked scale line on the test tube rack