Analyzers
Analysis Method: Coagulation method
Analysis Items: PT, APTT, TT, FIB
Throughput: 140 Tests/hour
SamplePositions: 5
Measuring Element: Grain
Moisture Range: 3 % to 35 %
Repeating Error: ≤ 0.2 %
Measuring Error: ≤ ± 0.5 %
Throughput: 200 Tests/hour
Analysis Method: End-point, Fixed-time, Rate(Kinetic)
Sample Positions: 37 sample positions
Reagent Position: 28 reagent positions
Throughput: Constant speed: 200 tests/hour
Max speed: 280 tests/hour
Analysis Method: End-point, Fixed-time, Rate(Kinetic)
Sample Positions: 49 sample positions
Reagent Position: 56 reagent positions
Throughput: 400 Test/hour
Analysis Method: End-point, Fixed-time, Rate(Kinetic)
Sample Positions: 60 or 90 sample positions, built-in barcode system available
Reagent Position: 90 refrigerated reagent positions
Throughput: 600 Tests/hour
Analysis Method: End-point, Fixed-time, Rate (Kinetic)
Sample Positions: 90 sample positions, built-in barcode system available
Reagent Position: 180 refrigerated reagent positions(R1:45 & R2:45)
Throughput: 800 Tests/hour
1200 Tests/hour with ISE (Optional)
Analysis Method: End-point, Fixed-time, Rate (Kinetic)
Sample Positions: 150 sample positions
Reagent Position: 180 reagent positions
Sample: Whole blood, Serum, Plasma, Dialysate, CSF
Input Parameters: Patient Temperature, Hemoglobin, FiO2, B.P.
Analysis Time: <90s
Test: pH(CH), pCO2, pO2, K,Na+, CL-, Ca++, Hct, B.P.
Sample: Whole blood, Serum, Plasma, Dialysate, CSF
Input Parameters: Patient Temperature, Hemoglobin, FiO2, B.P.
Analysis Time: <90s
Test: pH(CH), pCO2, pO2, K,Na+, CL-, Ca++, Hct, B.P.
Test Items: K, Na, Cl
Sample: Serum, Plasma, Whole blood, Cerebrospinal fluid and dilute urine
Measuring Speed: ≤25s
Analysis Method: lon selective electrode (ISE)
Test Items: K+, Na+, Cl-
Sample: Serum, Plasma, Whole blood, Cerebrospinal fluid and dilute urine
Measuring Speed: ≤25s
Analysis Method: lon selective electrode (ISE)
Test Items: K, Na, Cl, iCa, nCa, TCa, pH
Sample: Serum, Plasma, Whole blood, Cerebrospinal fluid and dilute urine
Measuring Speed: ≤25s
Analysis Method: lon selective electrode (ISE)
Test Items: K, Na, Cl, iCa, nCa, TCa, pH, TCO2, AG
Sample: Serum, Plasma, Whole blood, Cerebrospinal fluid and dilute urine
Measuring Speed: ≤25s
Analysis Method: lon selective electrode (ISE)
Test Items: K+, Na+, Cl-, iCa2+, nCa2+, TCa2+, pH, TCO2 and AG
Sample: Serum, Plasma, Whole blood, Cerebrospinal fluid and dilute urine
Measuring Speed: ≤25s
Analysis Method: lon selective electrode (ISE)
Test Items: K+, Na+, Cl-, iCa2+, nCa2+, TCa2+, pH, TCO2, AG, Li+ and Mg2+
Sample: Serum, Plasma, Whole blood, Cerebrospinal fluid and dilute urine
Measuring Speed: ≤25s
Analysis Method: lon selective electrode (ISE)
Test Items: K+, Na+, Cl-, iCa2+, nCa2+, TCa2+, pH, TCO2 and AG
Sample: Serum, Plasma, Whole blood, Cerebrospinal fluid and dilute urine
Measuring Speed: ≤25s
Analysis Method: lon selective electrode (ISE)
Application: Erythrocyte sedimentation rate analysis
Measuring: Principle Infrared sensor
Analysis Result: Westergren ESR value(mm/hr)
Throughput: Up to 80 samples per hour
Application: Erythrocyte sedimentation rate analysis
Measuring: Principle Infrared sensor
Analysis Result: Westergren ESR value(mm/hr)
Throughput: Up to 80 samples per hour
Temperature Range: RT +5℃~300℃
Measuring Range: 0.1~100%
Temperature Accuracy: ±1℃
Repeatability: Relative error 1%
Temperature Range: RT +5℃~280℃
Measuring Range: 0~100%
Temperature Accuracy: ±1℃
Sample Weight: 0.5~15g
Throughput: 60 tests/hour
Measuring principle: Coulter principle Colorimetry hemoglobin determination
Parameter: WBC, LYM#, MID#, GR#, LYM%, MID%, GR%, RBC, HGB
HCT, MCV, MCH, MCHC, RDW-SD
RDW-CV, PLT, MPV, PDW, PCT, P-LCR, P-LCC
Histograms: 3 Histograms (including WBC, RBC, PLT)
Throughput: 60 tests/hour
Measuring principle: Impedance for cell counting Cyanide-free method for HGB
Reagent: Lyse(500mL) and Diluent(20L)
Parameter: WBC, Neu#, Lym#, Mid#, Neu%, Lym%, Mid%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, P-LCR, NLR, PLR, PLCC
Throughput: 60 tests/hour
Assay Items: 5 parts, 29 parameters, 3 histograms, 3D scattergram
Principle: Tri-angle laser scatter, Flow cytometry method, 3D scattergram analysis, Impedance method for RBC and PLT counting, Cyanide-free method for HGB test
Test Mode: CBC mode, CBC+DIFF mode Venous whole blood, Capillary whole blood and Prediluted
Throughput: 60 samples/hour
Principle: Impedance for WBC Differentiation, WBC/RBC/PLT count colorimetric method for HGB test
Channel: 2
Parameters: 21 parameters (including MID#, GRAN#, LYM%, RBC, MCV, MCHC, RDW-CV, MPV, PCT, P-LCC, WBC, LYM#, MID%, GRAN%, HGB, HCT, MCH< RDW-SD, PLT, PDW, P-LCR)
Sample volume: Whole blood: 10µl, Pre-diluted: 20µl
Calibration: Manual calibration, Automatic calibration, and fresh blood calibration
Counting mode: Venous blood, Peripheral blood, Pre-diluted blood
Printing model: Auto-print, Manual print
Function: Chemistry + Coagulation
Photometry method: End point, Fixed time, Kinetic, Serum blank, Bi-chromatic, Two reagent, Multi-point etc.
Coagulation method: Nephelometry
Specific protein method: Nephelometry, Kinetic Nephelometry
Reading cuvette: Quartz flow through cell
Measuring volume: 450μl-800μl
Incubator: 20 incubating positions
Photometric system: Light Source:6V/1 OW halogen lamp; Standby function
Wavelength:340/405/492/510/546/578/620nm, 2 more filters available on request
Wavelength Accuracy: 土2nm
Test mode: Kinetic, End-point, Two point, Absorbance
Wavelength: 7 standard filters, 340, 405, 492, 510, 546, 578, 630 nm, 1 free position
Wavelength precision: ±2 nm, width ≤ 10nm
Absorbance range: 0~4.500 Abs
Measurement Range: 0-10000 mg/l
Detection Limit: 5 μg/l (ppb)
Detection method: Wet chemical Oxidation by UV
Detector: NDIR
Measurement Range: 0-1000 mg/l, which can be extended to 50,000mg/L by manual dilution
Detection Limit: TC (standard catalyst): 50 μg/l
TC (platinum aluminum catalyst: 100 μg/l
IC: 20 μg/l
Detection method: High-temperature catalytic combustion oxidation
Detector: NDIR
Measurement Range: 0-1000 mg/l, which can be extended to 50,000mg/L
Detection Limit: TC (standard catalyst): 50 μg/l
TC (platinum aluminum catalyst: 100 μg/l
IC: 20 μg/l
Detection method: High-temperature catalytic combustion oxidation
Detector: NDIR
Type: Offline
Measurement range: 0.001 to 1.5 mg/L (ppm)
Detection limit: 1 ppb
Maximum tolerance: ± 5%
Type: Online
Measurement range: 0.001 to 1.5 mg/L (ppm)
Detection limit: 1 ppb
Maximum tolerance: ± 5%
Wavelength: 480 - 680nm
Throughput: 120 Tests/hour
Display: LCD display
Test Items: PH, Nitrite, Protein, Glucose, Occult blood, Bilirubin, Urobilinogen, Ketone, Specific gravity, Leukocytes, Ascorbic Acid, Color, Limpidness, Creatinine, Microalbumin, Calcium
Wavelength: 525nm, 610nm, 660nm
Measurement Principle: Reflectometry
Test Items: Glucose, Ketone, Specific gravity, pH, Blood, Protein, Urobilinogen, Nitrite, Leukocyte, Ascorbic acid, Creatinine, Calcium and microalbumin
Test Speed: 120 Tests/hour
Wavelength: 525nm, 610nm, 660nm
Measurement Principle: Artificial Intelligence + Computer Vision Technology
Test Items: Glucose, Ketone, Specific gravity, pH, Blood, Protein, Urobilinogen, Nitrite, Leukocyte, Ascorbic acid, Creatinine, Calcium and microalbumin
Test Speed: 514 Tests/hour
Assay Method: Photoelectric colorimetric method
Test Speed: 240 Tests/hr (15 sec/strip)
Sample Racks: 6 test tube racks (6*10 samples)
Sample Volume: Minimum volume: 3ml