Thermal Cycler
Sample capacity(wells): 0.2ml PCR tubes x 96.8 x 12 PCR plate or 96 well plate x 1
Reaction volume: 10-50 μl
Thermal cycle technology: Peltier
Heating temperature range: 4 °C ~ 100 °C
Sample capacity(wells): 0.2ml PCR tubes x 96.8 x 12 PCR plate or 96 well plate x 1
Reaction volume: 10-50 μl
Thermal cycle technology: Peltier
Heating temperature range: 4 °C ~ 100 °C
Sample capacity(wells): 48
Reaction Volume: 5-100 μL
Consumables: 0.2 ml 8-strip tubes, 0.2 ml PCR single tube (Optical flat cap,clear tube)
Heating /cooling function: Heating / Cooling method: Peltier
Max heating rate: 8.0°C/sec
Max cooling rate: 6.2°C/sec
Average heating rate: 6.2°C/sec
Average cooling rate: 4.5°C/sec
Sample capacity(wells): 48
Reaction Volume: 5-100 μL
Consumables: 0.2 ml clear non-skirt 48 well plates, 8-tube strips, Single tubes
Heating /cooling function: Heating / Cooling method: Peltier
Max heating rate: 8.0°C/sec
Max cooling rate: 6.2°C/sec
Average heating rate: 6.2°C/sec
Average cooling rate: 4.5°C/sec
Sample capacity: 96x0.1ml PCR plate, 12x8-strip tubes, 96x0.1ml single tube (transparent cover)
Detection wavelength: 510 to 710 nm
Excitation wavelength: 455 to 645 nm
Sample volume range: 10 to 50 μl
Sample capacity: 96 wells
Reaction volume: 0-100 μl
Consumables: 0.2ml 96-well plates
0.2 ml 8-strip tubes, 0.2 ml PCR single tube (Optical flat cap, Clear tube)
Heating /cooling function: Heating /cooling method: Peltier
Max heating rate: 6.1°C/sec
Max cooling rate: 5.0°C/sec
Average heating rate: 4.5°C/sec
Average cooling rate: 5.0°C/sec
Sample capacity: 96 wells
Reaction volume: 0-100 μl
Consumables: 0.2ml 96-well plates
0.2 ml 8-strip tubes, 0.2 ml PCR single tube (Optical flat cap, Clear tube)
Heating /cooling function: Heating /cooling method: Peltier
Max heating rate: 6.1°C/sec
Max cooling rate: 5.0°C/sec
Average heating rate: 4.5°C/sec
Average cooling rate: 5.0°C/sec
Throughput: 96 well (12 × 8)
Applicable consumables: PCR single tube or strip, 96wellx0.2ml half skirted/no skirted plate
Dynamic range: 1-10x10 copies
Detection location: Top detection
Capacity: 16 x 0.2ml (2x8well, Dual block)
Consumable Clear: 0.2ml PCR tube/8-tube strips
Reaction volume: 15-100µl
Temperature: Temperature control technology: Customized peltier module
Temperature range: 0-100°C (resolution 0.1°C)
Temperature fluctuation: ±0.1°C
Temperature uniformity: ±0,25°C
Temperature accuracy: ±0,25°C
Sample capacity: 0.2mL PCR tubes×96, 8mL×12 PCR 8 strips or 96 well PCR plate
Heating temperature range: 4-105°C
Lid temperature range: 30-110°C
Temperature display accuracy: ±0.1°C
Sample capacity: 0.2mL PCR tubes×96, 8mL×12 PCR 8 strips or 96 well PCR plate
Heating temperature range: 4-105°C
Lid temperature range: 30-110°C
Temperature display accuracy: ±0.1°C
Block formats (choose 1 or more): 96×0.2ml (A), 54×0.5ml (B), 96×0.2ml+77x0.5ml (C), 384 well (D)
Temperature range: 0-99.9°C
Display interference: 7 inch LCD
Maximum heating ramp rate: 5.0°C/S
Block formats (choose 1 or more): 96×0.2ml (A), 54×0.5ml (B), 96×0.2ml+77x0.5ml (C), 384 well (D)
Temperature range: 0-99.9°C
Display interference: 5.7 inch LCD
Maximum heating ramp rate: 4.0°C/S
Block formats (choose 1 or more): 96×0.2ml (A), 54×0.5ml (B), 96×0.2ml+77x0.5ml ©
Temperature range: 0-100°C
Display interference: 5.7 inch LCD
Maximum heating ramp rate: 4.0°C/S (45-99°C)