Microwave Digestion System
Labdex Microwave Digestion System features high-pressure TFM vessels, aerospace composite fiber construction, real-time infrared temperature monitoring, and advanced Android-based control for efficient, uniform sample digestion in demanding laboratory applications.
- Microwave source: 2450MHz; Maximum microwave output power 2000W, emitted from dual magnetron inverter high-energy microwave field non-pulse continuous microwave output
- Installed power: 3800 W
- Microwave cavity: 316 L Stainless steel microwave resonant cavity, with a wall thickness of 3mm, sprayed with multi-layer PFA coating
Compare
- Microwave source: 2450 MHz; Maximum microwave output power 2000 W, emitted from dual magnetron inverter high-energy microwave field non-pulse continuous microwave output
- Installed power: 3800 W
- Microwave cavity: 316 L Stainless steel microwave resonant cavity, with a wall thickness of 3 mm, sprayed with multi-layer PFA coating
Compare
- Microwave source: 2450 MHz; Maximum microwave output power 2000 W, emitted from dual magnetron inverter high-energy microwave field non-pulse continuous microwave output
- Installed power: 3800 W
- Microwave cavity: 316 L Stainless steel microwave resonant cavity, with a wall thickness of 3 mm, sprayed with multi-layer PFA coating
Compare
- Microwave source: 2450 MHz; Maximum microwave output power 2000 W, emitted from dual magnetron inverter high-energy microwave field non-pulse continuous microwave output
- Installed power: 3800 W
- Microwave cavity: 316 L Stainless steel microwave resonant cavity, with a wall thickness of 3 mm, sprayed with multi-layer PFA coating
Compare
- Microwave source: 2450 MHz; Maximum microwave output power 2000 W, emitted from dual magnetron inverter high-energy microwave field non-pulse continuous microwave output
- Installed power: 3800 W
- Microwave cavity: 316 L Stainless steel microwave resonant cavity, with a wall thickness of 3 mm, sprayed with multi-layer PFA coating
Compare
- Microwave source: 2450 MHz, high-energy microwave field transmission
- Installed power: 1800 W
- Microwave cavity: 316 L Stainless steel cavity with Teflon coating
Compare
- Microwave source: 2450 MHz, high-energy microwave field transmission
- Installed power: 1800 W
- Microwave cavity: 316 L Stainless steel cavity with teflon coating
Compare
- Microwave source: 2450 MHz, high-energy microwave field transmission
- Installed power: 1800 W
- Microwave cavity: 316 L Stainless steel cavity with Teflon coating
Compare
- Vessel quantity: 6
- Pressure monitoring: Contactless pressure sensor
- All vessels: Scanning monitoring
Compare
- Vessel quantity: 8
- Pressure monitoring: Contactless pressure sensor
- All vessels: Scanning monitoring
Compare
- Vessel quantity: 10
- Pressure monitoring: Contactless pressure sensor
- All vessels: Scanning monitoring
Compare
- Vessel quantity: 6
- Temperature monitoring: Contactless IR Sensor temperature monitoring
Each vessel temperature controlled
Temperature controlling range: 50-400 ℃
Max. Working temperature: 250 ℃
Temperature accuracy: ±0.1 ℃ - Pressure monitoring: Contactless sensor pressure monitoring
Each vessel pressure controlled
Pressure controlling range: 0-15 Mpa
Max. Working pressure: 6 Mpa
Pressure accuracy: ±0.01 MPa
Compare
- Vessel quantity: 8
- Temperature monitoring: Contactless IR sensor temperature monitoring
Each vessel temperature controlled
Temperature controlling range: 50-400 ℃
Max. Working temperature: 250 ℃
Temperature accuracy: ±0.1 ℃ - Pressure Monitoring: Contactless sensor pressure monitoring
Each vessel pressure controlled
Pressure controlling Range: 0-15 Mpa
Max. Working pressure: 6 Mpa
Pressure accuracy: ±0.01 MPa
Compare
- Vessel quantity: 10
- Temperature monitoring: Contactless IR Sensor temperature monitoring
Each vessel temperature controlled
Temperature controlling range: 50-400 ℃
Max. Working temperature: 250 ℃
Temperature accuracy: ±0.1 ℃ - Pressure Monitoring: Contactless IR Sensor temperature monitoring
Each vessel temperature controlled
Temperature controlling range: 50-400 ℃
Max. Working temperature: 250 ℃
Temperature accuracy: ±0.1 ℃
Compare
- Vessel quantity: 12
- Temperature monitoring: Contactless IR Sensor temperature monitoring
Each Vessel temperature controlled
Temperature controlling range: 50-400 ℃
Max. working temperature: 250 ℃
Temperature accuracy: ±0.1 ℃ - Pressure Monitoring: Contactless sensor pressure monitoring
Each vessel pressure controlled
Pressure controlling range: 0-15 Mpa
Max. Working pressure: 6 Mpa
Pressure accuracy: ±0.01 Mpa
Compare
- Vessel quantity: 12
- Temperature monitoring: Contactless IR Sensor temperature monitoring
Each vessel temperature controlled
Temperature controlling range: 50-400 ℃
Max. Working temperature: 250 ℃
Temperature accuracy: ±0.1 ℃ - Pressure monitoring: Contactless sensor pressure monitoring
Each vessel pressure controlled
Pressure controlling range: 0-15 Mpa
Max. Working pressure: 6 Mpa
Pressure accuracy: ±0.01 MPa
Compare
- Vessel quantity: 18
- Temperature monitoring: Contactless IR Sensor temperature monitoring
Each vessel temperature controlled
Temperature controlling range: 50-400 ℃
Max. Working temperature: 250 ℃
Temperature accuracy: ±0.1 ℃ - Pressure monitoring: Contactless sensor pressure monitoring
Each vessel pressure controlled
Pressure controlling range: 0-15 Mpa
Max. Working pressure: 6 Mpa
Pressure accuracy: ±0.01 MPa
Compare
- Vessel quantity: 40
- Temperature monitoring: IR sensor temperature monitoring
Each vessel temperature controlled
Temperature controlling range: 50-400 ℃
Max. Working temperature: 250 ℃
Temperature accuracy: ±0.1 ℃ - Pressure onitoring: Contactless sensor pressure monitoring
Each vessel pressure controlled
Pressure controlling range: 0-15 Mpa
Max. Working pressure: 6 Mpa
Pressure accuracy: ±0.01 MPa
Compare