Analyzer
Labdex Analyzer are high-precision instruments designed for accurate and efficient analysis in laboratory and industrial settings. With advanced technology and intuitive interfaces, they provide reliable data across various applications, including research, quality control, clinical diagnostics, and environmental monitoring. These analyzers offer high sensitivity, fast response, and low maintenance.
Auto Coagulation Analyzer
Automatic Biochemistry Analyzer
Automatic Dry Biochemistry Analyzer
Blood Gas And Electrolyte Analyzer
COD Analyzer
Dissolved Gas Analyzer
Electrolyte Analyzer
ESR Analyzer
Fat Analyzer
Grain Moisture Meter
Halogen Moisture Analyzer
Hematology Analyzer
Microbial ID/AST System
Multitest Analyzer
Particle Size Analyzer
Semi-Auto Coagulation Analyzer
Semi-Automatic Chemistry Analyzer
TOC Analyzer
Urine Analyzer
- Analysis Method: Coagulation method
- Analysis Items: PT, APTT, TT, FIB
- Throughput: 140 Tests/hour
- Analysis Method: Coagulation method, Immunoturbidimetry
- Analysis Items: PT, APTT, TT, FIB, DD, FDP
- Throughput: 160 Tests/hour
- Test method: Coagulation (magnetic beads), Immunoturbidimetry & Chromogenic substrate
- Throughput: 200 Tests/hour
- Probe: 1
- Throughput: 200 Tests/hour
- Analysis Method: End-point, Fixed-time, Rate(Kinetic)
- Sample Positions: 37 sample positions
- Throughput: Constant speed: 200 tests/hour
Max speed: 280 tests/hour - Analysis Method: End-point, Fixed-time, Rate(Kinetic)
- Sample Positions: 49 sample positions
- Throughput: 400 Test/hour
- Analysis Method: End-point, Fixed-time, Rate(Kinetic)
- Sample Positions: 60 or 90 sample positions, built-in barcode system available
- Throughput: 600 Tests/hour
- Analysis Method: End-point, Fixed-time, Rate (Kinetic)
- Sample Positions: 90 sample positions, built-in barcode system available
- Throughput: 800 Tests/hour
1200 Tests/hour with ISE (Optional) - Analysis Method: End-point, Fixed-time, Rate (Kinetic)
- Sample Positions: 150 sample positions
- Throughput: Constant 200 tests/hour (mono or double reagent)
- Analysis principle: Colorimetric, turbidimetry
- Analysis method: 1 Point end, 2 point end, Fixed-Time, Kinetics
- Sample volume: 90 - 120 μl
- Bar code: 2-D bar code
- Test time: 12 min / sample
- Sample volume: 90 - 120 μl
- Bar code: 2-D bar code
- Test time: 12 min / sample
- Sample volume: 100 μL
- Bar code: QR code scanning
- Test time: 7 - 12 minutes
- Sample: Whole blood, Serum, Plasma, Dialysate, CSF
- Input Parameters: Patient Temperature, Hemoglobin, FiO2, B.P.
- Analysis Time: <90s
- Sample: Whole blood, Serum, Plasma, Dialysate, CSF
- Input Parameters: Patient Temperature, Hemoglobin, FiO2, B.P.
- Analysis Time: <90s
- Sample: Whole blood, Serum, Plasma, Dialysate, CSF
- Input parameters: Patient temperature, Hemoglobin, FiO, B.P.
- Analysis time: < 90 Seconds
- Measuring principle: Dichromate colorimetric method
- Range: 0 - 150 mg/L, 0 - 1500 mg/L
- Accuracy: ± 8 %
- Measuring principle: Fast digestion spectrophotometry
- Range: 10 - 10000 mg/L
- Accuracy: ≤ 5 %
- Detector: FID, TCD
- Minimum detection concentration (μl/L):
H₂ CO CO₂ CH₄ C₂H₄ C₂H₆ C₂H₂ 2 1 5 0.1 0.1 0.1 0.1 - Sampler: Packed column sampling, Capillary sampling, Six-port valve gas sampling
- Test Items: K, Na, Cl
- Sample: Serum, Plasma, Whole blood, Cerebrospinal fluid and dilute urine
- Measuring Speed: ≤25s
- Test Items: K+, Na+, Cl-
- Sample: Serum, Plasma, Whole blood, Cerebrospinal fluid and dilute urine
- Measuring Speed: ≤25s
- Test Items: K, Na, Cl, iCa, nCa, TCa, pH
- Sample: Serum, Plasma, Whole blood, Cerebrospinal fluid and dilute urine
- Measuring Speed: ≤25s
- Test Items: K, Na, Cl, iCa, nCa, TCa, pH, TCO2, AG
- Sample: Serum, Plasma, Whole blood, Cerebrospinal fluid and dilute urine
- Measuring Speed: ≤25s
- Test Items: K+, Na+, Cl-, iCa2+, nCa2+, TCa2+, pH, TCO2 and AG
- Sample: Serum, Plasma, Whole blood, Cerebrospinal fluid and dilute urine
- Measuring Speed: ≤25s
- Test Items: K+, Na+, Cl-, iCa2+, nCa2+, TCa2+, pH, TCO2, AG, Li+ and Mg2+
- Sample: Serum, Plasma, Whole blood, Cerebrospinal fluid and dilute urine
- Measuring Speed: ≤25s
- Test Items: K+, Na+, Cl-, iCa2+, nCa2+, TCa2+, pH, TCO2 and AG
- Sample: Serum, Plasma, Whole blood, Cerebrospinal fluid and dilute urine
- Measuring Speed: ≤25s
- Application: Erythrocyte sedimentation rate analysis
- Measuring: Principle Infrared sensor
- Analysis Result: Westergren ESR value(mm/hr)
- Application: Erythrocyte sedimentation rate analysis
- Measuring: Principle infrared sensor
- Analysis result: Westergren ESR value (mm/hr)
- Temperature Range: RT +5℃~300℃
- Measuring Range: 0.1~100%
- Temperature Accuracy: ±1℃
- Temperature Range: RT +5℃~280℃
- Measuring Range: 0~100%
- Temperature Accuracy: ±1℃
- Temperature range: RT to 300°C
- Capacity: 4 Pcs/batch
- Sample volume: 0 - 100 g
- Temperature range: RT to 300°C
- Capacity: 6 Pcs/batch
- Sample volume: 0 - 100 g
- Measuring Element: Grain
- Moisture Range: 3 % to 35 %
- Repeating Error: ≤ 0.2 %
- Capacity: 110 g
- Readability: 10 mg
- Temperature range: 40 to 199°C
- Capacity: 110 g
- Readability: 5 mg
- Temperature range: 40 to 199°C
- Capacity: 110 g
- Readability: 2 mg
- Temperature range: 40 to 199°C
- Capacity: 110 g
- Readability: 1 mg
- Temperature range: 40 to 199°C
- Capacity: 110 g
- Readability: 1 mg
- Temperature range: 40 to 199°C
- Capacity: 110 g
- Readability: 1 mg
- Temperature range: 40 to 199°C
- Range: 110 g
- Readability: 1mg
- Temperature range: 40 to 230 °C
- Range: 110 g
- Readability: 1mg
- Temperature range: 40 to 230 °C
- Range: 210 g
- Readability: 1mg
- Temperature range: 40 to 230 °C
- Range: 210 g
- Readability: 1mg
- Temperature range: 40 to 230 °C
- Range: 110 g
- Readability: 1mg
- Temperature range: 40 to 199°C
- Range: 110 g
- Readability: 1mg
- Temperature range: 40 to 199°C
- Range: 110 g
- Readability: 0.1mg
- Temperature range: 40 to 199°C
- Range: 110 g
- Readability: 0.1mg
- Temperature range: 40 to 199°C
- Throughput: 60 tests/hour
- Measuring principle: Coulter principle Colorimetry hemoglobin determination
- Parameter: WBC, LYM#, MID#, GR#, LYM%, MID%, GR%, RBC, HGB
HCT, MCV, MCH, MCHC, RDW-SD
RDW-CV, PLT, MPV, PDW, PCT, P-LCR, P-LCC
- Throughput: 60 samples/hour
- Principle: Impedance for WBC Differentiation, WBC/RBC/PLT count colorimetric method for HGB test
- Channel: 2
- Throughput: 70 Samples / hour
- Principle: Electrical resistance for counting and SFT method of hemoglobin
- Channel: 2
- Throughput: 60 Tests/hour
- Assay Items: 5-part WBC differentiation with 29 parameters, 2 histograms, a 3D scattergram, and 1 BASO scatter plot
- Principle: Sheath-flow technology, multi-angle laser scatter, impedance method, Cyanide-free reagent
- Throughput: ≥ 90 Sample per hour
- Sample volume: Whole bloods 10 uL, pre-dilutes 20 uL
- Sample type: Whole blood, peripheral blood, pre-dilute
- Throughput: Up to 90 samples per hour
- Sample volume: Whole blood 10 μL, Pre-diluted 20 μL
- Sample type: Whole blood, PLT only, HB only, Capillary pre-dilution, Diluent, Control, Calibrator
- Sample volume: Whole blood: 10µl, Pre-diluted: 20µl
- Calibration: Manual calibration, Automatic calibration, and fresh blood calibration
- Counting mode: Venous blood, Peripheral blood, Pre-diluted blood
- Sample volume: Whole blood: 20 µl, pre-diluted: 20 µl
- Calibration: Manual, automatic and fresh blood calibration
- Counting mode: Whole blood, capillary whole blood, pre-diluted
- Testing principle: Colorimetry for microbial identification
Turbidimetry for AST - Data interpretation: Automatic and manual
- Identification: Capable of identifying Enterobacteriaceae, non-fermenting bacteria, Staphylococci, Streptococci, yeast-like fungi, etc
- Function: Chemistry + Coagulation
- Photometry method: End point, Fixed time, Kinetic, Serum blank, Bi-chromatic, Two reagent, Multi-point etc.
- Coagulation method: Nephelometry
- Test range: 0.1 μm to 800 μm
- Test speed: < 1 min/ times (excluding sample dispersion time)
- Number of detector channels: 86
- Test range: Wet process: 0.01 μm to 1250 μm
Dry process:0.1 μm to 1250 μm - Test speed: < 1 min/ times (excluding sample dispersion time)
- Number of detector channels: Wet process: 112
Dry process: 102
- Testing principle: Optical colorimetry
- Testing Channel: 2 (can test different projects at the same time)
- Display: 5
- Testing principle: Optical colorimetry
- Testing Channel: 4 (can test different projects at the same time)
- Display: 5
- Testing principle: Optical colorimetry
- Testing channel: 4
- Display: LED Display
- Testing principle: Optical colorimetry
- Testing channel: 4 (Can test different projects at the same time)
- Display: 7 Inch color touch LCD screen
- Reading cuvette: Quartz flow through cell
- Measuring volume: 450μl-800μl
- Incubator: 20 incubating positions
- Test mode: Kinetic, End-point, Two point, Absorbance
- Wavelength: 7 standard filters, 340, 405, 492, 510, 546, 578, 630 nm, 1 free position
- Wavelength precision: ±2 nm, width ≤ 10nm
- Test: Colorimetric method, Turbidimetry, Coagulation method
- Test method: 1 Point end, 2 Point end, Kinetics, Fixed-Time, Percentage method, Turbidimetry
- Sample type: Serum, Plasma, Urine, Cerebrospinal fluid, Pleural and abdominal water, etc
- Measurement Range: 0-10000 mg/l
- Detection Limit: 5 μg/l (ppb)
- Detection method: Wet chemical Oxidation by UV
- Measurement Range: 0-1000 mg/l, which can be extended to 50,000mg/L by manual dilution
- Detection Limit: TC (standard catalyst): 50 μg/l
TC (platinum aluminum catalyst: 100 μg/l
IC: 20 μg/l - Detection method: High-temperature catalytic combustion oxidation
- Measurement Range: 0-1000 mg/l, which can be extended to 50,000mg/L
- Detection Limit: TC (standard catalyst): 50 μg/l
TC (platinum aluminum catalyst: 100 μg/l
IC: 20 μg/l - Detection method: High-temperature catalytic combustion oxidation
- Type: Offline
- Measurement range: 0.001 to 1.5 mg/L (ppm)
- Detection limit: 1 ppb
- Type: Online
- Measurement range: 0.001 to 1.5 mg/L (ppm)
- Detection limit: 1 ppb
- Measurement range: 0-1000mg/L, can extend to 0-100,000mg/L (Automatically dilution)
- Measurement method: High temperature catalytic combustion
- Detector: NDIR
- Measurement range: 0-1000mg/L, can extend to 0-100,000mg/L
- Measurement method: High temperature catalytic combustion
- Detector: NDIR
- Measurement range: 0.001 mg/L - 1 mg/L (1 - 1000 ppb)
- Measuring limit: 0.001 mg/L
- Conductivity detection range: 0.055 μs/cm - 8.000 μs/cm
- Wavelength: 480 - 680nm
- Throughput: 120 Tests/hour
- Display: LCD display
- Wavelength: 525nm, 610nm, 660nm
- Measurement Principle: Reflectometry
- Test Items: Glucose, Ketone, Specific gravity, pH, Blood, Protein, Urobilinogen, Nitrite, Leukocyte, Ascorbic acid, Creatinine, Calcium and microalbumin
- Wavelength: 525nm, 610nm, 660nm
- Measurement Principle: Artificial Intelligence + Computer Vision Technology
- Test Items: Glucose, Ketone, Specific gravity, pH, Blood, Protein, Urobilinogen, Nitrite, Leukocyte, Ascorbic acid, Creatinine, Calcium and microalbumin
- Assay Method: Photoelectric colorimetric method
- Test Speed: 240 Tests/hr (15 sec/strip)
- Sample Racks: 6 test tube racks (6*10 samples)
- Assay method: Flow cell digital imaging technology, medical image fusion technology, artificial intelligence identification technique
- Test speed: 120 Tests/hr
- Channel: Four channels fixed flow counting cell
- Throughput: 30 Sample/hour
- Measurement principle: Machine-vision technology, automatic identification, classification, counting, and morphological analysis of formed urinary elements using microscopy
- Sample volume: Minimum urine volume: 2 ml
Minimum injection volume: 1 ml
- Throughput: 30 - 40 Sample/hour
- Measurement principle: Machine-vision technology, automatic identification, classification, counting, and morphological analysis of formed urinary elements using microscopy
- Sample volume: Minimum urine volume: 2 ml
Minimum injection volume: 1 ml