Spectrophotometers
O2 Enriched Flame: No
Air-C2H2 flame: Yes
Auto sampler: No
Wavelength range: 190-900nm
Wavelength range: 190-900nm
Wavelength accuracy: ≤±0.25nm
Wavelength repeatability: ≤0.15nm
Baseline stability: Static: Zero Drift of Baseline ≤0.005Abs/30min, Baseline transient noise≤0.001Abs
Dynamic: Zero Drift of Baseline ≤0.005Abs/10min, Baseline transient noise≤0.005Abs
Wavelength range: 190-900nm
Wavelength accuracy: Better than ±0.20nm
Baseline stability: 0.006A/30min
Light source system: Array
Wavelength range: 190-900nm
Light source system: Array
Optical system: Array
Graphite furnace: Array
Wavelength range: 190-900nm
Wavelength accuracy: ≤±0.25 nm
Wavelength repeatability: ≤±0.15nm
Spectral bandwidth: ≤±0.02 nm
Wavelength range: 190-900nm
Wavelength accuracy: ≤±0.25nm
Wavelength repeatability: ≤±0.15nm
Spectral bandwidth: ≤±0.02nm
Wavelength range: 190-900nm
Wavelength accuracy: ≤±0.25nm
Wavelength repeatability: ≤±0.15nm
Spectral bandwidth: ≤±0.02nm
Wavelength range: 190-900nm
Wavelength accuracy: ≤±0.25nm
Wavelength repeatability: ≤±0.15nm
Spectral bandwidth: ≤±0.02nm
Wavelength range: 190-900nm
Wavelength accuracy: ≤±0.25nm
Wavelength repeatability: ≤±0.15nm
Spectral bandwidth: ≤±0.02nm
Optical system: Double beam, Grating 1200 lines/mm
Wavelength range: 190 ~ 1100 nm
Spectral bandwidth: 2 nm
Wavelength accuracy: ±0.1nm@656.1nm, ±0.3nm@all
Optical system: Double beam, Grating 1200 lines/mm
Wavelength range: 190 ~ 1100 nm
Spectral bandwidth: 1 nm
Wavelength accuracy: ±0.1nm@656.1nm, ±0.3nm@all
Optical system: Double beam, Grating 1200 lines/mm
Wavelength range: 190 ~ 1100 nm
Spectral bandwidth: 0.5 nm, 1 nm, 2 nm, 4 nm, 5 nm
Wavelength accuracy: ±0.1nm@656.1nm, ±0.3nm@all
Optical system: Double beam, Grating 1200 lines/mm
Wavelength range: 190 ~ 1100 nm
Spectral bandwidth: 2 nm
Wavelength accuracy: ±0.1nm@656.1nm, ±0.3nm@all
Optical system: Double beam, Grating 1200 lines/mm
Wavelength range: 190 ~ 1100 nm
Spectral bandwidth: 1 nm
Wavelength accuracy: ±0.1nm@656.1nm, ±0.3nm@all
Optical system: Double beam, Grating 1200 lines/mm
Wavelength range: 190 ~ 1100 nm
Spectral bandwidth: 0.5 nm, 1 nm, 2 nm, 4 nm, 5 nm
Wavelength accuracy: ±0.1nm@656.1nm, ±0.3nm@all
Excitation source: 150 W Xenon lamp
Excitation wavelength: 200 nm to 900 nm
Emission wavelength: 200 nm to 900 nm
Excitation slit: 1 nm, 2 nm, 5 nm, 10 nm, 20 nm
Excitation source: 150 W Xenon lamp
Excitation wavelength: 200 nm to 900 nm
Emission wavelength: 200 nm to 900 nm
Excitation slit: 1 nm, 2 nm, 5 nm, 10 nm, 20 nm
Excitation source: 150 W Xenon lamp
Excitation wavelength: 200 nm to 900 nm
Emission wavelength: 200 nm to 900 nm
Excitation slit: 2 nm, 5 nm, 10 nm, 20 nm
Optical system: Single beam
Monochromator: C-T monochromator, blazed holographic grating 1200 lines/nm
Wavelength range: 340-1020 nm
Spectral bandwidth: 4nm (2nm Optional)
Optical system: Single beam
Monochromator: C-T monochromator, blazed holographic grating 1200 lines/nm
Wavelength range: 195-1020 nm
Spectral bandwidth: 4nm (2nm Optional)
Optical system: Single beam
Monochromator: C-T monochromator, blazed holographic grating 1200 lines/nm
Wavelength range: 320-1100 nm
Spectral bandwidth: 4nm (2nm Optional)
Optical system: Single beam
Monochromator: C-T monochromator, blazed holographic grating 1200 lines/nm
Wavelength range: 190-1100 nm
Spectral bandwidth: 4nm (2nm Optional)
Optical system: Single beam
Monochromator: C-T monochromator, blazed holographic grating 1200 lines/nm
Wavelength range: 320-1100 nm
Spectral bandwidth: 2nm (1nm Optional)
Optical system: Single beam
Monochromator: C-T monochromator, blazed holographic grating 1200 lines/nm
Wavelength range: 190-1100 nm
Spectral bandwidth: 2nm (1nm Optional)
Wavelength range: 200-800 nm
Minimum sample size: 0.5-2.0 μl
Path length: 0.2 mm 1.0 mm
Light source: Xenon flash lamp
Wavelength range: 200-800 nm
Minimum sample size: 0.5-2.0 μl
Path length: 0.2 mm 1.0 mm
Light source: Xenon flash lamp
Wavelength range: 260 nm, 280 nm
Minimum sample size: 1.0-2.0 μl
Path length: 0.5 mm
Light source: UV LED
Wavelength range: 200-800 nm
Minimum sample size: 0.5-2.0 μl
Path length: 0.05 mm, 0.2 mm, 1.0 mm
Light source: Xenon flash lamp
Optical System: Double Beam, Grating 1200 lines/mm
Wavelength Range: 190-1100 nm
Spectral Bandwidth: 2 nm
Wavelength Repeatability: <=0.1nm
Optical System: Double Beam, Grating 1200 lines/mm
Wavelength Range: 190-1100 nm
Spectral Bandwidth: 1 nm
Wavelength Repeatability: <=0.1nm
Optical System: Single Beam, Grating 1200 lines/mm
Wavelength Range: 190-1100 nm
Spectral Bandwidth: 2 nm
Wavelength Accuracy: ±0.1nm @ 656.1nm, ±0.3nm @ all
Optical System: Single Beam, Grating 1200 lines/mm
Wavelength Range: 190-1100 nm
Spectral Bandwidth: 1 nm
Wavelength Accuracy: ±0.1nm @ 656.1nm, ±0.3nm @ all
Optical System: Single Beam, Grating 1200 lines/mm
Wavelength Range: 190-1100 nm
Spectral Bandwidth: 0.5/1/2/4/5 nm
Wavelength Accuracy: ±0.1nm @ 656.1nm, ±0.3nm @ all
Optical System: Double Beam, Grating 1200 lines/mm
Wavelength Range: 190-1100 nm
Spectral Bandwidth: 2 nm
Wavelength Accuracy: ±0.1nm @ 656.1nm, ±0.3nm @ all
Optical System: Double Beam, Grating 1200 lines/mm
Wavelength Range: 190-1100 nm
Spectral Bandwidth: 1 nm
Wavelength Accuracy: ±0.1nm @ 656.1nm, ±0.3nm @ all
Optical System: Double Beam, Grating 1200 lines/mm
Wavelength Range: 190-1100 nm
Spectral Bandwidth: 0.5/1/2/4/5 nm
Wavelength Accuracy: ±0.1nm @ 656.1nm, ±0.3nm @ all
Optical system: Single beam, grating 1200 lines/ mm
Wavelength range: 190 to 1000 nm
Bandwidth: 2 nm
Wavelength accuracy: ±2nm
Optical system: Single beam, grating 1200 lines/ mm
Wavelength range: 190 to 1000 nm
Bandwidth: 2 nm
Wavelength accuracy: ±1nm
Optical system: Single beam, grating 1200 lines/ mm
Wavelength range: 190 to 1100 nm
Bandwidth: 2 nm
Wavelength accuracy: ±0.5 nm
Optical system: Single beam, grating 1200 lines/ mm
Wavelength range: 190 to 1100 nm
Bandwidth: 2 nm
Wavelength accuracy: ±0.5 nm
Optical system: Single beam, grating 1200 lines/ mm
Wavelength range: 190 to 1100 nm
Bandwidth: 2 nm
Wavelength accuracy: ±0.1nm@656.1nm, ±0.3nm@all
Optical system: Single beam, grating 1200 lines/ mm
Wavelength range: 190 to 1100 nm
Bandwidth: 1 nm
Wavelength accuracy: ±0.1nm@656.1nm, ±0.3nm@all
Optical system: Single beam, grating 1200 lines/ mm
Wavelength range: 190 to 1100 nm
Bandwidth: 0.5/1/2/4/5 nm
Wavelength accuracy: ±0.1nm@656.1nm, ±0.3nm@all
Wavelength Range: 190-1100nm
Spectral Bandwidth: 4nm
Optical System: Single Beam, Grating 1200 lines/mm
Wavelength Accuracy: ±0.5nm
Optical system: Double beam, grating 1200 lines/ mm
Wavelength range: 190 to 1100 nm
Spectral bandwidth: 2 nm
Wavelength accuracy: ±0.1nm@656.1nm, ±0.3nm@all
Optical system: Double beam, grating 1200 lines/ mm
Wavelength range: 190 to 1100 nm
Spectral bandwidth: 2 nm
Wavelength accuracy: ±0.1nm@656.1nm, ±0.3nm@all
Optical system: Double beam, grating 1200 lines/ mm
Wavelength range: 190 to 1100 nm
Spectral bandwidth: 0.5/1/2/4/5 nm
Wavelength accuracy: ±0.1nm@656.1nm, ±0.3nm@all
Optical system: Single beam, grating 1200 lines/ mm
Wavelength range: 190 to 1100 nm
Spectral bandwidth: 2 nm
Wavelength accuracy: ±0.1nm@656.1nm, ±0.3nm@all
Optical system: Single beam, grating 1200 lines/ mm
Wavelength range: 190 to 1100 nm
Spectral bandwidth: 1 nm
Wavelength accuracy: ±0.1nm@656.1nm, ±0.3nm@all
Optical system: Single beam, grating 1200 lines/ mm
Wavelength range: 190 to 1100 nm
Spectral bandwidth: 0.5/1/2/4/5 nm
Wavelength accuracy: ±0.1nm@656.1nm, ±0.3nm@all
Wavelength range: 360 nm to 780 nm
Wavelength pitch: 10 nm
Sensor: Silicon photodiode array
Grating method: Concave grating
Wavelength range: 360 nm to 780 nm
Wavelength pitch: 10 nm
Sensor: Dual-row high-precision CMOS array sensor
Grating method: Concave grating
Wavelength range: 360 nm to 780 nm
Wavelength pitch: 10 nm
Sensor: Dual-row high-precision CMOS array sensor
Grating method: Concave grating
Illumination system: d/0 (Diffused lighting, 0° observation viewing)
(conform to CIE No. 15, ISO 7724/1, ASTM E1164, DIN 5033 TeiL7, JIS Z8722 condition C Standard)
40 mm, avian fully diffuse reflective surface coating: 40 mm, avian fully diffuse reflective surface coating
Illumination light source: CLEDs
Sensor: Dual optical sensor array
Wavelength range: 360 nm to 780 nm
Wavelength pitch: 10 nm
Sensor: Differential spectrum engine
Grating method: Concave grating
Wavelength range: 360 nm to 780 nm
Wavelength pitch: 10 nm
Sensor: Differential spectrum engine
Grating method: Concave grating
Wavelength range: 360 nm to 780 nm
Wavelength pitch: 10 nm
Sensor: Differential spectrum engine
Grating method: Concave grating
Optical system: Single beam, grating 1200 lines/mm
Wavelength range: 340nm ~ 1020 nm
Spectral bandwidth: 6 nm
Wavelength accuracy: ±3 nm
Optical system: Single beam, grating 1200 lines/mm
Wavelength range: 320nm ~ 1020 nm
Spectral bandwidth: 5 nm
Wavelength accuracy: ±2 nm
Optical system: Single beam, grating 1200 lines/mm
Wavelength range: 320nm ~ 1020 nm
Spectral bandwidth: 4 nm
Wavelength accuracy: 2 nm
Optical system: Single beam, grating 1200 lines/mm
Wavelength range: 330nm ~ 1100 nm
Spectral bandwidth: 2 nm
Wavelength accuracy: ± 0.5 nm
Optical system: Single beam, grating 1200 lines/mm
Wavelength range: 340nm ~ 1050 nm
Spectral bandwidth: 4 nm
Wavelength accuracy: 1 nm
Optical system: Single beam, grating 1200 lines/mm
Wavelength range: 320nm ~ 1100 nm
Spectral bandwidth: 2 nm
Wavelength accuracy: ±0.1 nm@656.1nm, ±0.3 nm@all
Optical System: Single Beam, Grating 1200 lines/mm
Wavelength range: 320-1100nm
Spectral bandwidth: 4 nm
Wavelength accuracy: 2 nm
Optical System: Single Beam, Grating 1200 lines/mm
Wavelength range: 190-1100nm
Spectral bandwidth: 2 nm
Wavelength accuracy: 2 nm
Optical System: Single Beam, Grating 1200 lines/mm
Wavelength range: 190-1020nm
Spectral bandwidth: 5 nm
Wavelength accuracy: ±2 nm
Optical System: Double Beam, Grating 1200 lines/mm
Wavelength Range: 190-1100 nm
Spectral Bandwidth: 2 nm
Wavelength Accuracy: ±0.1nm@656.1nm, ±0.3nm@all
Optical System: Double Beam, Grating 1200 lines/mm
Wavelength Range: 190-1100 nm
Spectral Bandwidth: 1 nm
Wavelength Accuracy: ±0.1nm@656.1nm, ±0.3nm@all
Optical System: Double Beam, Grating 1200 lines/mm
Wavelength Range: 190-1100 nm
Spectral Bandwidth: 0.5/1/2/4/5 nm
Wavelength Accuracy: ±0.1nm@656.1nm, ±0.3nm@all
Optical System: Double Beam, Grating 1200 lines/mm
Wavelength Range: 190-1100 nm
Spectral Bandwidth: 2 nm
Wavelength Accuracy: ±0.1nm@656.1nm, ±0.3nm@all
Optical System: Double Beam, Grating 1200 lines/mm
Wavelength Range: 190-1100 nm
Spectral Bandwidth: 1 nm
Wavelength Accuracy: ±0.1nm@656.1nm, ±0.3nm@all
Optical System: Double Beam, Grating 1200 lines/mm
Wavelength Range: 190-1100 nm
Spectral Bandwidth: 0.5/1/2/4/5 nm
Wavelength Accuracy: ±0.1nm@656.1nm, ±0.3nm@all
Optical system: Double Beam
Wavelength range: 190-1100 nm
Spectral bandwidth: 1.8 nm
Wavelength accuracy: ±0.3 nm
Optical system: Double Beam
Wavelength range: 190-1100 nm
Spectral bandwidth: 1 nm
Wavelength accuracy: ±0.3 nm
Optical system: Double Beam
Wavelength range: 190-1100 nm
Spectral bandwidth: 0.5/1/2/4/5 nm
Wavelength accuracy: ±0.3 nm