Horizontal Autoclave LX121HA

Description

Horizontal Autoclave LX121HA is a fully automatic horizontal cylindrical design structure with chamber, jacket and mineral glass wool insulation, which is conducive to the steam first entering the jacket for preheating, ensuring the preheating of the sterilization chamber and the uniformity of the drying temperature. The chamber and door are made of SUS 304, the jacket, boiler, water tank, steam generator, pipeline is made of SUS 304 and the outer shell is made of stainless steel sprayed. Equipped with LCD color touch screen operation with Microcomputer control system, preset professional and systematized sterilizing programs, testing program and user-defined program.

Specifications

Volume 80 L
Chamber size Ø380 x 700 mm
Design pressure -0.1/0.3Mpa
Design temperature 150℃
Working temperature range 105℃-138℃
Max working pressure 0.23Mpa
Sterilization time range 0-99 min
Drying time range 0-99 min
Temperature accuracy 0.1℃
Control Microcomputer
Display 5 inch LCD color touch screen
Steam generator Built-in steam generator
Door Safety interlock door, with safety shield and switch
Loading Sterilization tray
Water tank Yes
Drying function Yes
Printer Built-in printer
Voltage 220/380V. 50/60Hz, 1-phase/3-phase
Power 5.7 kW
Outer dimension 985 x 600 x 1450 mm
Net weight 120 kg
Packing dimension 1180 x 800 x 1650 mm
Gross weight 145 kg
Features
  • 5-inch color touch screen operation
  • Automatic fault detection, convenient for self-maintenance
  • Water injection, pulsing, heating up, sterilizing, and vacuum drying processes are fully automatic
  • Equipped with 0.22um HEPA filter
  • Equipped with water level cut-off sensor and water level indicator. If water shortage, the machine will stop running
  • A fault warning system is designed, and fault messages are shown on touch screen display in real-time
  • Beep will sound once the sterilization cycle completes and messages are shown on the touch display at the same time
  • The door opening mechanism cannot be operated until the pressure in the chamber and it can't be started if the door doesn't close well
  • The safety valve will be open automatically when the inner pressure is over 0.24 MPa, and the steam will be exhausted to the water link
  • The whole chamber and water tank are made of stainless steel 304
  • Built-in printer, USB port records the entire sterilization cycle
Applications
  • Used to sterilize rubber, liquid, plant-in instrument, dressing, hollow instrument, wrapped and unwrapped items in various like ophthalmology, operation room, laboratory etc.
Standard Accessories
  • 2 layers of shelves
Optional Accessories
  • Aluminium panel
  • 7-inch touch screen + PLC control screen