Low Speed Centrifuge LX134LSC
Description
Low Speed Centrifuge LX134LSC is a table top unit with a low speed of up to 5500 rpm for effective separation and filtration of given samples. Equipped with microcomputer controller which automatically calibrates and sets centrifugal force value concerning its required speed. HD large, LCD panel for viewing ongoing parameters with simultaneous regulation of speed and time. Integrated with overheat, over speed, electric lid-locking system, automatic rotor distinguish, and self-balancing technique.
Specifications
| Maximum speed |
5500 rpm |
|---|---|
| Maximum RCF |
5952 x g |
| Maximum capacity |
4 x 750 ml |
| Noise |
≤ 62 dB (A) |
| Revolutions/min |
± 10 r/min |
| Timer |
1 s ~ 99 h 59 min |
| Rotor automatic recognition |
Yes |
| Voltage |
AC 220±22V; 50Hz; 10A |
| Power |
1000 W |
| Dimension (H x W x D) |
465 x 580 x 400 mm |
| Net weight |
60 Kg |
| Packing dimension (W x D x H) |
760 x 880 x 710 mm |
| Gross weight |
130 Kg |
Features
- Centrifugal speed – 5500 rpm
- Having steel structure with SS centrifuge chamber that provide environmental friendly anticorrosion coating treatment
- Built-in over-speed, over-heat, and unbalance protection with electric lid lock safety function
- It has up to 10 levels of acceleration/deceleration with linear drive
- Equipped with a microcomputer controller, AC frequency conversion brush-less motor with fast speed and stable operation
- It has five groups of user-defined preset programs
- It can store 99 program groups
- Two modes can be set: start timing and arrival revolution timing
- Equipped with a special noise reduction system
- An intimate tool rack is provided for accompanying tools to guard the instrument at all times
- The front of the fuselage is designed with an operation SOP guide map, which makes it easier and more standard for laboratory users
- Came with a rotor cover that can be quickly locked for easy use
- Ergonomic, low opening height, close the centrifuge cover with one press
Applications
- Used in life science, biochemical, and clinical labs for precipitate separation and serum analysis, in the pharmaceutical industry, etc., and is perfect for DNA, RNA, PCR, or antibody analysis.
Rotor Selection
| Rotor name | Maximum speed (rpm) | Maximum capacity (ml) | Maximum RCF (xg) |
| Angle rotor 01 | 5500 | 40 x 15 (W) | 5073 |
| Angle rotor 02 | 5500 | 6 x 50 (W) | 3645 |
| Swing-out rotor 01 | 4000 | 120 x 2~7 (Blood collection tube) | 3184 |
| Swing-out rotor 02 | 4000 | 4 x 750 (Round bucket) | 3309 |
| Swing-out rotor 03 | 4000 | 4 x 750 (Round bucket with biosafety lid) | 3309 |
| Swing-out rotor 04 | 4000 | 4 x 750 (Square bucket) | 3309 |
| Swing-out rotor 05 | 4000 | Auto uncap 104 x 2-7 (Blood collection tube) | 3309 |
| Swing-out rotor 06 | 4000 | 4 x 500 (Round bucket) | 3184 |
| Swing-out rotor 07 | 4000 | 4 x 500 (Round bucket with biosafety lid) | 3184 |
| Swing-out rotor 08 | 4000 | 4 x 500 ml (Square bucket) | 3184 |
| Swing-out rotor 09 | 4000 | Auto uncap 64 x 2~7 (Blood collection tube) | 3040 |
| Swing-out rotor 10 | 4000 | 4 x 250 (Round bucket) | 3040 |
| Swing-out rotor 11 | 4000 | 4 x 250 (Round bucket with biosafety lid) | 3040 |
| Swing-out rotor 12 | 4000 | 4 x 250 (Square bucket) | 3040 |
| Swing-out rotor 13 | 4000 | 4 x 250 (Conical bucket, corning tube) | 3040 |
| Swing-out rotor 14 | 4000 | 6 x 250 (Round bucket) | 3040 |