Vertical Autoclave LX144VA

Description

Vertical Autoclave LX144VA is a sterilizing mechanism with top loading sterilizer along with safety protection features like an LCD display system, safety interlock door, over temperature, pressure and electric protection, lid closing checking, dry scorch protection, automatic release safety valve. It adopts a working environment of 5 - 40°C and relative humidity of 10 % - 85 %. This mechanism is very effectively useful in hospitals, clinical laboratories, research centers, and science colleges for the sterilization of glass wares, biological materials, cultural media, surgical instruments, rubber material, etc.

Specifications

Capacity
120 L
Chamber dimension
Φ 500 x 658 mm
Stainless steel basket
(Φ 480 x 250) mm x 2 Pcs
Temperature accuracy
0.1°C
Working environment
5 - 40°C, Relative humidity not greater than 85 %
Display
Color LCD touch screen
Chamber material
SUS 304 Steel
Sterilization temperature
105 - 138°C
Range of sterilization time
1 - 6000 Minutes
Melting temperature
60 - 115°C
Range of dissolving time
1 - 6000 Minutes
Warming temperature
45 -79°C
Range of warming time
1 - 9999 Minutes
Cooling lock open
40 - 99°C For solid, waste, agar, self-defined, 40 - 80°C for liquid
Exhaust
Automatic internal discharging Exhaust speed can be selected by 6 levels
Opening way
Up and down, one-touch open
Range of pressure gauge
-0.1-0.5 MPa
Pressure valve set temperature
0.29 MPa
Cooling type
Fast cooling fan
Interface
USB
Power supply
4600 W, Single phase 220 V ± 10 %, 25 A, 50/60 Hz
External dimension
665 x 790 x 1040 mm
Net weight
155 Kg
Packing dimension
760 x 790 x 1240 mm
Gross weight
210 Kg
Features
  • It has an electric double inner lock for real-time monitoring of the opening and closing state
  • Having the lid locking system with one key unlock
  • The system monitors the temperature changes in the sterilization chamber in real time
  • It has a large 7 inch color LCD touch screen display
  • Sterilization record storage system which can store 999 cycles sterilization process
  • Sterilization through six different exhaust speeds can be selected according to the substances
  • Sterilization data can be converted into curves through software
  • Equipped with the cooling process at the end of the sterilization chamber
  • Supports electrical protection, power cut alarm system
Applications
  • Vertical Autoclave is used in Biotechnology, microbiology, the medical and healthcare industry, scientific research centers, schools, colleges, and universities for the sterilizing process.
Optional Accessories
  • Auto water fill
  • Drying
  • Dedorization
  • Micro-printer
  • Condenser
  • SUS316 Steel material
  • Pharma packing testing program
  • Floating PT100 sensor
  • Printing set (Printer + digital pressure sensor)
  • Auto-drainage
  • App control/Remote control