Flow Cytometer LX102FCM is a high-performance system with triple-laser, 15-channel fluorescence detection, delivering high-resolution and stable analysis. It enables fully automated, high-throughput operation with real-time processing up to 50,000 events per second. The system features automatic fluorescence compensation, accurate volumetric counting, and supports both 40-tube racks and 96-well microplates for efficient workflow.

Catalog
Specifications
Laser Up to 3 lasers 488 nm (60 nw), 638 nm (80 nw), 405 nm (100 mw)
Single range Maximum 10⁷
Detector APD
Fluorescence resolution CV < 2%
Fluorescence sensitivity FITC < 50 MESF, PE < 30 MESF, APC < 30 MESF
Fluorescence linearity ≥ 0.99
Forward scattered light resolution < 0.45 µm
Detection particle range 0.2 - 50 µm
Carryover rate < 0.1 %
Detection speed > 50000 Events
Injection speed Low: 15 µl/Min, Medium: 30 µl/Min
High1: 60 µL/Min, High2: 90 µl/Min, High3: 120 µl/Min
Adjustable speed range: 15 - 120 µl/Min
Injection mode Single tube manual sampling
40 Tubes auto sampler with single sample mixing function
96 Holes plates
PC Memory 8 G/HDD, 1T/27 inch monitor
External dimension 760 x 450 x 470 mm
Net weight 50 Kg
Features
  • Three lasers, 15-channel fluorescence detection

  • High-resolution, high-sensitivity, and stable optical performance

  • Fully automated acquisition with synchronized collection and real-time analysis

  • High-throughput processing up to 50,000 events/sec injection rate

  • Database-driven automatic fluorescence compensation (no reconfiguration required)

  • Absolute volumetric counting via precision plunger pump system

  • Automated sampling for 40-tube racks and 96-well microplates

Applications
  • Used for rapid, quantitative analysis of cells, including immune phenotyping, cell cycle analysis, apoptosis studies, and biomarker detection in clinical and research applications. It is widely applied in oncology, immunology, stem cell research, and microbial analysis for accurate cell characterization and disease monitoring.

Standard Accessories
  • Computer

Optional Accessories
  • Auto-sampler

Configuration
Laser wavelengthChannelFilter Recommended fluorescent dyes
488 nmLX1525/40FITC, EGFP, BB515, Alexa Fluor 488
488 nmLX2575/30PE, DsRed
488 nmLX3620/30PE-Texas Red, ECD, PI, 7-AAD
488 nmLX4697/60PerCP, PE-Cy5, PerCP-Cy5.5, PE-Cy5.5, BB700, PerCP-eFlour710
488 nmLX5780/60PE-Cy7, PE-Alexa Flour 750
638 nmLX6670/20APC, Cy5, Alexa Fluor 647
638 nmLX7720/40APC-R700, Alexa Fluor 680, Alexa Fluor 700
638 nmLX8780/60APC-Cy7, APC-eFluor780, APC-H7
405 nmLX9425/20BV421
405 nmLX10460/40Pacific Blue, V450, BV480
405 nmLX11525/40BV510, V500
405 nmLX12605/40BV605
405 nmLX13660/40BV650
405 nmLX14720/40BV711
405 nmLX15780/60BV786, BV750
Download Catalog

Flow Cytometer

Labdex Flow Cytometer is a powerful analytical instrument used to identify, count, and characterize cells or particles by measuring their physical and fluorescent properties. It enables high-throughput, multipara-metric analysis for research, clinical diagnostics, immunology, and biotechnology applications.