Automated ELISA Processor LX1005AEP is a fully automated laboratory system integrating sample dispensing, incubation, shaking, washing, and microplate reading. It features high-precision pipetting, 8 independent photometric channels, and a 400-700 nm spectral range for accurate analysis. With two temperature-controlled shaking incubators, a 16-channel washer, 10 filter positions, and bidirectional LIS connectivity supporting HL7, it delivers efficient and consistent laboratory testing.
| Spectral range | 400 -750 nm |
|---|---|
| Absorbance | 0.0 - 4.0 OD |
| Reading channels | 8 Independent photometric channels |
| Pipetting range | 5 - 1000 µl |
| Pipetting precision | (100 µl) CV ≤ 1.0%, accuracy ≤ 2.5% (1000 µl) CV ≤ 0.5%, accuracy ≤ 1.0% |
| Linear range | 0.000 - 3.000 Abs |
| Repeatability | CV < 1.5% |
| Stability | ≤ ± 0.003 Abs |
| Incubation | 16 Shaking incubators |
| Incubation temperature | RT to 60°C |
| Temperature uniformity | ± 0.5°C |
| Temperature fluctuation | ± 0.5°C |
| Shaking function | Horizontal circular oscillation, 1-3 levels adjustable, amplitude 2.5 mm |
| Cover position | 4 (16 Covers) |
| Heating method | Dry heating with cover |
| Working temperature | 10°C to 30°C |
| Working humidity | 40% - 70% |
| Washer head | 16 Channels (32 pin), double row cleaning, hanging installation, with leakage recovery |
| Washing residual | < 1 µl |
| Injection uniformity | CV < 1.5% |
| Reading accuracy | ≤ ± 0.02 Abs from 0.0 to 1.0 OD ≤ ± 0.03 Abs from 1.0 to 2.0 OD |
| Optical filters | 4 Standard filters (405 nm, 450 nm, 492 nm, 630 nm) Total 10 filter positions |
| Sensitivity | ≥ 0.01 mg/l |
| Channel difference | ≤ 0.02 Abs |
| Liquid level detection | Air pressure level detection, needle blocking intelligent detection |
| Sample racks | 12 x 20 Push pull sample rack with detection |
| Sample channel | 8 Channels |
| TIP | 5 TIP racks |
| Reagent racks | 6 Reagent positions, 40 quality control positions + 12 reagent bottles + 25 reagent tanks (reagent tank with code identification) |
| Software | Above windows 7 system |
| LIS System | Bi-direction, support HL7 protocol |
| Result | Software-based absorbance and results review |
| Power supply | AC 100 V/240 V, 50/60 Hz |
| External dimension & Net weight | Main unit: 1925 x 824 x 1652 mm; 320 Kg Base stand: 1925 x 792 x 777 mm; 153 Kg |
| Packing dimension & Gross weight | Main unit: 2100 x 950 x 1160 mm; 430 Kg Base stand: 2100 x 950 x 1010 mm; 255 Kg Accessories: 1560 x 930 x 530 mm; 130 kg |
Pressure-based liquid detection with tip and clot detection
High-precision pipetting with a minimum volume of 5 µl
8 Independently controlled injection channels with Y-Z movement
Disposable tips to minimize cross-contamination
Intelligent gripper with real-time position sensing
Adjustable gripper spacing and strength for different microplates
Dual-thread control for simultaneous, interference-free operation
16 Independent temperature-controlled shaking incubation modules with three-level shaking
Three independent microplate washers for efficient washing
Built-in high-precision microplate reader
Single and dual-wavelength detection with 10 filter positions
UV Lamp for ultraviolet illumination
LED Light for illumination and visual indication
IAP Function for integrated automated processing
Wide absorbance range with high sensitivity and excellent repeatability
Stable performance for automated ELISA testing