Atomic Absorption Spectrophotometer LX701AAS is fully automatic single flame atomization system device. Designed for air-acetylene flame method analysis and flame emission method analysis. It has modular electronic circuits design with easy operation and maintenance. Equipped with reliable gas-liquid separator and fuel gas filter device provide the robustness even in high humid and harsh environment.

Catalog
Specifications
Wavelength range 190-900nm
Wavelength accuracy Better than ±0.20nm
Baseline stability 0.006A/30min
Light source system
Lamp turretMotorized 8-lamp turret (Two high performance HCLs can be mounted on the turret to increase the sensitivity in flame analysis)
Lamp current adjustment0~15mA
Optical system
MonochomatorSingle beam, Czerny-Turner design grating monochromator
Grating1800 lines/mm
Blazed wavelength250nm
Focal length277mm
Spectral bandwidth0.1nm, 0.2nm, 0.4nm, 0.8nm,1.6nm, auto-switch over
Flame atomizer
Burner10cm single slot all-titanium burner
Spray chamberCorrosion resistant all-plastic spray chamber
NebulizerHigh efficiency glass nebulizer with metal sleeve, sucking up rate:6-7ml/min
Detection and Data processing system
DetectorR928 Photomultiplier with high sensitivity and wide spectral range.
SoftwareUnder windows operating system
Analytical methodWorking curve auto-fitting; standard addition method; automatic sensitivity correction, automatic calculation of concentration and content
Repeat times1-99 times, automatic calculation of mean value, standard deviation and relative standard deviation
Multi-task functionsSequential measurement for multi-element determination to the same sample
Condition readingWith model function
Result printingMeasurement data and final analytical report printout, editing with Excel
Function expansion Hydride vapor generator can be connected for hydride analysis
Packing dimension (L x W x H) and Gross weight 1280 x 750 x 830 mm, 150 kgs
Features
  • Equipped with high performance PMT as the detector

  • Provided with automatic 8-lamp turret, automatic adjustment of lamp current and optimization of light beam position

  • To perform flame emission analysis, flame emission burner head can be installed for alkali metals

  • Parameters like Wavelength scanning, peak picking, change in spectral bandwidth, optimization of position parameters, automatic ignition and gas flow setting are done automatically

  • Data processing system: provided with analytical methods – Working curve auto-fitting standard addition method, automatic sensitivity correction, automatic calculation of concentration and content with windows operating system software

  • Experiments can be repeated 1~99 times along with automatic calculation of mean value, standard deviation and relative standard deviation

  • Equipped with multi task functions- sequential determination of multi-elements in the same sample, condition reading- with model function and result printing- measured data and final analytical report printout in excel

  • Provided with standard RS-232 serial port connection

  • In order to increase the sensitivity in flame analysis, two high performance HCLs can be mounted on the lamp turret

  • The optical system consisting of outer light path, C-T type grating monochromatic, and back light path, which is in the upper right of the instrument, is controlled by the computer

  • Real-time monitoring of flame status, air pressure, etc. Automatically shutting off the gas circuit and alarm in abnormal status

  • Equipped with alarm and automatic protection to fuel gas leakage, abnormal flow, insufficient air pressure and abnormal flame extinction in flame system

Applications
  • Used for testing the metal element concentration analyze in agriculture, chemical, environmental study, food, mining, and petrochemical, pharmaceutical industry.

Atomic Absorption Spectrophotometer

Labdex Atomic Absorption Spectrophotometer is designed for precise elemental analysis with high sensitivity and accuracy. It features stable light sources, advanced optical systems, and efficient background correction. It is widely used in environmental testing, pharmaceuticals, metallurgy, food safety, and chemical laboratories for trace metal analysis.

Double Beam Spectrophotometer

Labdex Double Beam Spectrophotometer ensures high photometric accuracy by continuously comparing sample and reference beams. It offers excellent wavelength stability, low noise, and automatic baseline correction. It is ideal for research laboratories, quality control, pharmaceutical, and biochemical analysis.

Touch Screen Double Beam Spectrophotometer

Labdex Touch Screen Double Beam Spectrophotometer combines advanced optics with an intuitive touch interface. It ensures high accuracy, real-time data display, and user-friendly operation. It is widely used in pharmaceutical analysis, biotechnology, and research laboratories.

Touch Screen Single Beam Spectrophotometer

Labdex Touch Screen Single Beam Spectrophotometer features a modern interface, fast operation, and reliable performance. It is ideal for routine absorbance measurements in educational laboratories, research centers, and quality control environments.

Single Beam Spectrophotometer

Labdex Single Beam Spectrophotometer offers cost-effective and reliable absorbance measurements. It features simple operation, stable optics, and accurate wavelength control. It is ideal for educational institutions, routine laboratory work, and quality control testing.