Horizontal Autoclave LX270HA

Horizontal Autoclave LX270HA

Horizontal laboratory autoclave LX270HA is a double-door, rectangular, horizontal and triple-layer design fully automatic controlled autoclave that disinfects and sterilizes objects with saturated steam. It has a vertical sliding door with an effective sterilization temperature of 150 °C. Having safety features (like auto door, automatic shutoff preventing current overload, overpressure and temperature protective device, etc.), automatic drainage control system and steam generator user can also set up new cycles new cycles using the user-defined cycle to modify the parameters of all preset cycles as needed.

Generate Catalog
Capacity120 L
Inner chamber dimension (L × W × H)450 × 450 × 650 mm
Design temperature150 ℃
Design pressure-0.1/0.3Mpa
Working temperature range105 ℃ - 139 ℃
Working pressure range0 - 0.25Mpa
Temperature control accuracy≤±0.2 ℃
Temperature display accuracy0.1 ℃
Sterilization time range0-999min
Drying time range0-999min
Vacuum rate-97Kpa
Temperature equilibrium≤±0.5 ℃
Safety valve open pressure0.28Mpa
Steam Pressure and the consumption0.3 - 0.6 MPa and 10 kg/cycle
Water Source Pressure and the consumption0.15 - 0.3 MPa and 70 kg/cycle
Compressed air Pressure0.4 - 0.7 MPa
ControlPLC + HMI + Printer
InterfaceUSB, Ethernet
Power supply14 kW
Outer dimension (L × W × H)1190 × 1700 × 1000 mm
Net weight520 kg
Packing dimension1390 × 1900 × 1180 mm
Gross weight700 Kg

Front loading, 7-inch color touch screen display to monitor working status and parameters

Motorized or sliding door with pneumatic sealing to prevent loss of sterile steam

Built-in PLC + HMI+ printer

Built-in standard steam generator

Having 6 preset sterilization cycles, 4 User-defined cycles, and Testing cycles (B&D test and vacuum leakage test) and the user can create more new cycles if needed

Contains an aluminum silicate insulating layer for the best insulation technique

Equipped with an independent temperature monitoring system, the controller system has four-level password access, and a pneumatic angle pipeline system with removable filter plugs to prevent clogging

Perfect fault information prompt and fault self-diagnosis function

Door safety interlock feature: The door cannot be opened till the pressure inside the chamber doesn’t fall to 0

Automatic power cut off with alarm with low water levels indication

Used in medical, research, microbiological, pharmaceutical, food industry and clinical departments for sterilization and also to sterilize the waste before discarding.
Loading shelves x 2 pcs
Remote monitoring system
Noise reduction configuration
Data logger
10-inch touch screen
ERP system
Programme Temperature Sterilization time Drying time
Unwrapped instruments 134°C 6 mins 8 mins
Wrapped instruments 134°C 7 mins 15 mins
Textile program 134°C 7 mins 15 mins
Implant program 134°C 10 mins 15 mins
Liquid program 121°C 20 mins No
Rubber 121°C 20 mins 15 mins
Hollow 134°C 6 mins 10 mins
Prions 134°C 18 mins 15 mins
PCD 134°C 3.5 mins 15 mins
Bowie-Dick test 134°C 3.5 mins 5 mins