Table Top Spectrophotometer LX202TS is based on real-time dual optical path spectrum analysis technology which monitors the energy fluctuation and interference of light source during the measurement guaranteeing the instrument measuring accuracy and the long-term repeatability index. Equipped with an Inter-instrument agreement and provides two kinds of light sources. It adopts reflectance D/8° and transmittance D/0° geometry to measure both opaque and transparent materials with flexible fixtures to turn the camera viewfinder function for positioning measurement of small samples.
| Wavelength range | 360 nm to 780 nm |
|---|---|
| Wavelength pitch | 10 nm |
| Sensor | Dual-row high-precision CMOS array sensor |
| Grating method | Concave grating |
| Sphere diameter | 152 mm |
| Half bandwidth | 1 nm |
| Reflectance range | 0 to 200% |
| Resolution | 0.0001 |
| Light source | Pulse xenon lamps and LEDs |
| UV measurement | Including UV, 400nm cutoff, 420nm cutoff, 460nm cutoff |
| Operating temperature | 5°C to 40°C |
| Storage temperature | 20°C to 45°C |
| Relative humidity | 80% RH (at 35°C) below no condensation |
| Measurement time | SCI/SCE < 2s (single mode) SCI+SCE < 4s |
| Measurement aperture | Reflectance: XLAV Φ25.4mm/Φ30mm LAVΦ15mm/Φ18mm, MAVΦ8mm/Φ11mm SAVΦ3mm/Φ6mm Transmittance: Φ17mm/Φ25mm (Auto aperture size recognition) |
| Viewing angles | 2° and 10° Standard observer |
| Transmittance sample size | No limit on sample width and height Thickness ≤ 50mm |
| Repeatability | ΔE*ab≤0.01 Spectral reflectance/transmittance≤0.1% |
| Long-term repeatability | XLAV chromaticity value: standard deviation ΔE*ab within 0.015 (For any temperature change at 20°C±10°C, measure the white calibration plate every hour within 24 hours) |
| Inter-instrument agreement | XLAV ΔE*ab 0.2 |
| Illuminants | A, B, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, U30, U35, DLF, NBF, TL83, TL84, ID50, ID65, LED-B1, LED-B2, LED-B3, LED-B4, LED-B5, LED-BH1, LED-RGB1, LED-V1, LED-V2 |
| Display | Spectral data, spectral graph, chromaticity data, color difference data, color difference graph, pass/fail judgment, simulated color, color evaluation, haze, liquid chromaticity, color bias |
| Color space | CIE LAB, CIE LUV, LCh, Hunter Lab, Yxy, XYZ, Musell, s-RGB, βxy |
| Chromatic aberration formula | ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc, ΔE*94, ΔE*00, ΔEab(hunter), 555 color classification |
| Chromaticity Index | WI (ASTM E313-20, ASTM E313-73, CIE/ISO, AATCC, Hunter, Taube, Berger Stensby), YI (ASTM D1925, ASTM E313-20, ASTM E313-73) Tint (ASTM E313-20), metamerism index Milm, staining fastness, color fastness, ISO brightness, R457, A density, T density, E density, M density, APHA/Hazen/Pt-Co (platinum cobalt index), Gardner (Gardner index), Saybolt (Saybolt index), Astm color, haze total transmittance, hiding power, strength, strength |
| Lighting/light receiving system | Reflection: d/8(diffuse lighting, 8° direction reception), transmission :d/ 0 (diffuse lighting, vertical direction reception) SCI(including specular reflected light)/SCE(not including specular reflected light) measurement at the same time Compliance with: CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, DIN5033 Teil7, JIS Z8722 Conditions C, ASTM E1164, ASTM-D1003-07 |
| Other functions | Camera framing and positioning The instrument can measure sideways, upwards and downwards (with accessories) Automatic temperature and humidity compensation function |
| Interface | USB, USB-B, RS-232 |
| Screen size | 7 inches capacitive touch screen |
| Storage memory | 8 GB U Disk for data storage and transfer |
| Power | 12V/3A |
| Dimension | 650 x 450 x 450 mm |
| Weight | 11 kg |
7-inch capacitive touch screen, Android operating system
Use BCRA series standard color tiles for color transfer and color value traceability to ensure excellent inter-station consistency
The excellent photoelectric test system scheme of the spectrophotometer makes the repeatability accuracy
Dual optical paths spectrum analysis technology
Compatibility with SCI/SCE measurement system
Inter-instrument agreement
4 test apparatus
Remove sample size limits by allowing users access to the transmission sample compartment
Four types of UV test modes
Used for the color and transmittance measurement in industrial samples like petroleum and oil, textile and yarn, pellet materials and packing material, etc.
Power adapter
Data cable
Fixture for transmittance
USB flash disk
Black cavity
White and Green board
30mm, 18mm, 11mm and 6mm apertures x 1pcs
Support table
Colorimetric dish
Damping handle
Heating transmission fixture (Including control circuit)
Vertical bracket
Pneumatic jacking rod (Including control circuit)
Small sample holding accessories
Reflection cubed bracket corrosion-resistant plate (Not removable)
Fiber test box
Film fixture
Trace transmission fixture
Rod box
Labdex Table Top Spectrophotometer is designed for laboratory convenience with robust construction and high performance. It offers precise measurements, easy sample handling, and long-term stability. It is suitable for clinical laboratories, research facilities, and industrial testing.
Labdex Atomic Absorption Spectrophotometer is designed for precise elemental analysis with high sensitivity and accuracy. It features stable light sources, advanced optical systems, and efficient background correction. It is widely used in environmental testing, pharmaceuticals, metallurgy, food safety, and chemical laboratories for trace metal analysis.
Labdex Double Beam Spectrophotometer ensures high photometric accuracy by continuously comparing sample and reference beams. It offers excellent wavelength stability, low noise, and automatic baseline correction. It is ideal for research laboratories, quality control, pharmaceutical, and biochemical analysis.
Labdex Touch Screen Double Beam Spectrophotometer combines advanced optics with an intuitive touch interface. It ensures high accuracy, real-time data display, and user-friendly operation. It is widely used in pharmaceutical analysis, biotechnology, and research laboratories.
Labdex Touch Screen Single Beam Spectrophotometer features a modern interface, fast operation, and reliable performance. It is ideal for routine absorbance measurements in educational laboratories, research centers, and quality control environments.