Whatsapp
Table Top Spectrophotometer LX302TS

Table Top Spectrophotometer LX302TS

Table Top Spectrophotometer LX302TS is a dual optical path design based on a differential spectroscopy engine and 1nm grating spectrum analysis technology which monitors the energy fluctuation and interference of light source during the measurement of sample signal guaranteeing the instrument measuring accuracy and the long-term repeatability index up to dE*ab ≤ 0.005. Equipped with an Inter-instrument agreement and provides two kinds of light sources. It adopts reflectance D/8° and transmittance D/0° geometry to measure both opaque and transparent materials with automatic calibration technology that confirms the long-term uniformity of fluorescence measurements.

Generate Catalog
Wavelength range360 nm to 780 nm
Wavelength pitch10 nm
SensorDifferential spectrum engine
Grating methodConcave grating
Sphere diameter152 mm
Half bandwidth1.6 nm
Reflectance range0 to 200 %
Resolution0.0001
Light sourcePulse xenon lamps and LED
UV measurement IncludingUV, 400nm cutoff, 420nm cutoff, 460nm cutoff
Operating temperature5°C to 40°C
Storage temperature20°C to 45°C
Relative humidity80% RH (at 35°C) below no condensation
Measurement timeSCI/SCE < 2s (Single mode)
SCI+SCE < 4s
Measurement aperture reflectanceXLAV Φ25.4mm/Φ30mm
LAVΦ15mm/Φ18mm, MAVΦ8mm/Φ11mm
SAVΦ3mm/Φ6mm
Transmittance: Φ17mm/Φ25mm (Auto aperture size recognition)
Viewing angles2° and 10° Standard observer
Transmittance sample sizeNo limit on sample width and height
Thickness ≤ 50mm
RepeatabilityΔE*ab≤0.005
Spectral reflectance/transmittance≤0.1%
Long-term repeatabilityXLAV chroma value: standard deviation ΔE*ab within 0.1 (0℃-40℃ arbitrary temperature change)
XLAV chroma value: standard deviation ΔE*ab 0.01 or less (under constant temperature conditions, the white correction plate is measured every hour within 24 hours)
Inter-instrument agreementXLAV ΔE*ab 0.08
IlluminantsA, B, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, U30, U35, DLF, NBF, TL83, TL84, ID50, ID65, LED-B1, LED-B2, LED-B3, LED-B4, LED-B5, LED-BH1, LED-RGB1, LED-V1, LED-V2
DisplaySpectral data, Spectrogram, chromaticity data, color difference Data, chromaticity map, pass/fail Judgment, Simulation color, Color evaluation, fog, liquid chromaticity, Color bias
Color spaceCIE LAB, CIE LUV, LCh, Hunter Lab, Yxy, XYZ, Musell, s-RGB, βxy
Chromatic aberration formulaΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc, ΔE*94, ΔE*00, ΔEab(hunter), 555 color classification
Chromaticity indexWI (ASTME31320, ASTME31373, CIE, ISO2470/R457, AATCC, Hunter, Taube, Berger stensby), YI(ASTMD1925, ASTM E313-20, ASTM E313-73), Tint(ASTM E313-20), Isochromatic index milm, color fastness, color changing fastness, ISO brightness, R457, A density, T density, E density, M density, APHA/Hazen/Pt-Co(platinum-cobalt index), Gardner(Gardner Index), Saybolt(Seibert Index), Astm color, fog, total transmittance, covering power, force, intensity
Lighting/light receiving systemReflection: d/8(diffuse lighting, 8° direction reception), transmission:d/ 0 (diffuse lighting, vertical direction reception)
SCI(including specular reflected light)/SCE(not including specular reflected light) measurement at the same time
Compliance with: CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, DIN5033 Teil7, JIS Z8722 Conditions C, ASTM E1164, ASTM-D1003-07
InterfaceUSB, USB-B, RS-232, Bluetooth
Screen size7 Inches capacitive touch screen
Storage memory8 GB U Disk for data storage and transfer
Power12V/3A
Camera positioningUltra HD camera (1400dp)
Automatic calibrationCan greatly improve the long-term repeatability of the instrument
Fluorescence calibrationCan automatically adjust the UV intensity, and ensure that the value of the instrument is highly consistent with that of other imported instruments when measuring materials containing fluorescence
Brightness calibrationThrough the brightness calibration algorithm, the real color of ultra-dark samples is restored
Other functionsPC side software save sample image function
The instrument can measure sideways, upwards and downwards (with accessories)
Automatic temperature and humidity compensation function
Dimensions (L × W × H)650 x 450 x 450 mm
Weight11 kg

7-inch capacitive touch screen, Android operating system

37 standard light sources and 40+measurement indicators

Using the MEMS process makes the color measurement more accurate on the basis of 1nm spectral resolution

Self-developed fluorescence calibration technique

Recording visual data while collecting data for obtaining further details on the sample

Dual optical paths spectrum analysis technology

Compatibility with SCI/SCE measurement system

Inter-instrument agreement

4 apertures switching with automatic recognition and allows the measurement of samples having many shapes

Four types of UV test modes

Support PC end export or printing of data test reports

Used for the color and transmittance measurement in industrial samples like petroleum and oil, textile and yarn, pellet materials and packing material, etc.
Power adapter
USB cable
Fixture for transmittance
Software U disk
Black cavity
White and Green board
30mm, 18mm, 11mm and 6mm apertures
Support table
Colorimetric dish
Heating transmission fixture (including control circuit)
Vertical bracket
Pneumatic jacking rod (including control circuit)
Small sample holding accessories
Reflection cupping plate (not removable)
Fiber test box
Film fixture
Micro transmission fixture
Rod box

Related Products