It is a benchtop high speed refrigerated centrifuge having 18500 rpm speed. Designed with a microprocessor-controlled system and LED digital display to visualize working parameters. Equipped with a brushless frequency motor and an automatic electric locking system. It has protection safety features against over-speed, and automatic rotor imbalance that provides highly precise results. Its dual-core processor makes it compatible for high/low speed and large/small capacity.

Catalog
Specifications
Maximum speed 18500 rpm
Maximum RCF 23990 x g
Maximum capacity 4 x 300 ml
Temp. Range -20 °C to 40 °C
Acceleration / Deceleration profiles 10 Kinds
Temp. Accuracy ± 1 ℃
Speed accuracy ±20 rpm
RPM/RCF Convert Yes
Timer range 0 - 99 hr. 59 min
Noise ≤ 60dB
Power AC 220V/110V 50 - 60 Hz
Dimension (W x D x H) 680 x 720 x 430 mm
Net weight 125 kg
Packaged dimension 850 x 760 x 560 mm
Gross weight 140 kg
Features
  • Centrifugal speed-18500 rpm 

  • The body of centrifuge is contracted with high-quality steel 

  • Enables easy and quick loading of samples 

  • 10 different acceleration and deceleration speeds available 

  • 10 different programs can be stored in the memory 

  • A wide range of rotors that are compatible with the instrument are available 

  • Adapters can be designed as per the experimental requirement

Applications
  • Used in clinical medicine, biochemistry, genetic engineering, immunology, and other fields. It is a necessary instrument for centrifugation in hospitals, research institutes, universities, etc.

Rotor Selection
Rotor nameMaximum speed (rpm)Maximum capacity (ml)Maximum RCF x g
Swing out rotor 0140004 x 24 x 73150
Swing out rotor 0240004 x 24 x 52750
Swing out rotor 0340004 x 16 x 103150
Swing out rotor 0440004 x 22 x 52840
Swing out rotor 0540004 x 18 x 103140
Swing out rotor 0650004 x 1 x 504730
Swing out rotor 0750004 x 1 x 1004730
Swing out rotor 0840004 x 2 x 503200
Swing out rotor 0940004 x 4 x 153200
Swing out rotor 1040004 x 6 x 153200
Swing out rotor 1140004 x 8 x 153200
Swing out rotor 1240004 x 8 x 10/7 (Vacuum tube)2770
Swing out rotor 1340004 x 8 x 5 (Vacuum tube adapter)2380
Swing out rotor 1440004 x 6 x 10/7 (Vacuum tube)2770
Swing out rotor 1540004 x 6 x 5 (Vacuum tube adapter)2380
Swing out rotor 1640004 x 4 x 10/7 (Vacuum tube)2770
Swing out rotor 1740004 x 4 x 5 (Vacuum tube adapter)2380
Swing out rotor 1840004 x 16 x 5 (Vacuum tube) 2520
Swing out rotor 1940004 x 16 x 7 (Vacuum tube) 2880
Swing out rotor 2040004 x 12 x 10 (Vacuum tube) 2880
Swing rotor 01 40004 x 300 (Round bucket)3180
Swing rotor 0240004 x 300 (Square bucket)3150
Swing rotor 03150004 x 519920
Fixed rotor 01140004 x 8 PCR 12070
Fixed rotor 02130006 x 8 PCR 16080
Fixed rotor 03140008 x 8 PCR 13390
Fixed rotor 041300012 x 8 PCR 17220
Fixed rotor 051400040 x 0.519960
Fixed rotor 061850012 x 1.523990
Fixed rotor 071500024 x 1.520600
Fixed rotor 081350030 x 1.519340
Fixed rotor 091100048 x 1.512840
Fixed rotor 101500016 x 519350
Fixed rotor 11140006 x 1016460
Fixed rotor 121300012 x 1017030
Fixed rotor 131100016 x 1013950
Fixed rotor 14110008 x 1512730
Fixed rotor 15900012 x 159590
Fixed rotor 16500024 x 153500
Fixed rotor 17500030 x 153830
Fixed rotor 18120006 x 3014000
Fixed rotor 19120006 x 50 (Conical) 16050
Fixed rotor 20120006 x 50 (Round)15960
Fixed rotor 21500012 x 503860
Fixed rotor 22400024 x 502970
Fixed rotor 23110004 x 8513560
Fixed rotor 24100004 x 10010310
Fixed rotor 2580006 x 1007280
Fixed rotor 26400012 x 1002970
Fixed rotor 271200024 Capillaries 15800
Vertical rotor 011600016 x 516450
Vertical rotor 02140008 x 3019750
Microplate rotor 01 40002 x 4 x 96 Hole (Frame type)2910
Microplate rotor 0240002 x 4 x 96 Hole (Box type)2770

Mini Centrifuge

We at Labex offers series of Mini Centrifuges with a speed range of 10000 rpm maximum. It is widely used to extract DNA / RNA samples, sedimentation of biological components, biochemical, chemical analysis of microsamples and separation of trace blood cells.

Mini Plate Centrifuge

We at Labex offers series of Mini Plate Centrifuges with a speed range of 2500 rpm maximum. It is widely used in molecular laboratory before and after thermal cycling to improve PCR yield.